Commit Graph

122 Commits

Author SHA1 Message Date
Vaishnav S
afc5f82d8d Fix typos related to units 2019-02-27 13:23:27 +01:00
Vaishnav S
5ca5e67cc6 Units: Typo "Square/Cubic Thous" -> "Square/Cubic Thou" 2019-02-25 11:43:41 +01:00
a0d0d37ecd Fix T61666: missing NULL_UNIT that stops iteration over units 2019-02-18 14:25:34 +01:00
de13d0a80c doxygen: add newline after \file
While \file doesn't need an argument, it can't have another doxy
command after it.
2019-02-18 08:22:12 +11:00
5657d68a03 Units: allow short unit names be case sensitive when needed.
To distinguish mW and MW without having to deviate from the standard
SI unit abbreviation. For all other units there are no changes.
2019-02-17 16:46:40 +01:00
ce5d079a49 Units: add support for light power units in Watt. Use for Eevee lights.
This affects point, spot and area lights. Sun light strength remains without
a unit. This change does not affect .blend file compatibility in any way, as
with the rest of the unit system it's purely a display and editing feature.

Not used for Cycles yet, that will be done after unifying the settings with
Eevee.
2019-02-17 16:23:00 +01:00
eef4077f18 Cleanup: remove redundant doxygen \file argument
Move \ingroup onto same line to be more compact and
make it clear the file is in the group.
2019-02-06 15:45:22 +11:00
744f633986 Cleanup: trailing commas
Needed for clan-format not to wrap onto one line.
2019-02-03 14:59:11 +11:00
65ec7ec524 Cleanup: remove redundant, invalid info from headers
BF-admins agree to remove header information that isn't useful,
to reduce noise.

- BEGIN/END license blocks

  Developers should add non license comments as separate comment blocks.
  No need for separator text.

- Contributors

  This is often invalid, outdated or misleading
  especially when splitting files.

  It's more useful to git-blame to find out who has developed the code.

See P901 for script to perform these edits.
2019-02-02 01:36:28 +11:00
f91b21f85b Cleanup: move comments above definitions
For clang-format not to wrap definitions.
2019-01-14 16:30:43 +11:00
6439ed844e Cleanup: remove tabs after line start
Allows expanding tabs before running clang-format.
2019-01-11 10:53:21 +11:00
22ddd57363 Fix T60338: Allow user to input units of another system 2019-01-09 10:40:05 +01:00
12e9d52882 Fix T60327: Value input with adaptive imperial units not working properly 2019-01-08 19:20:56 +01:00
9d52ff1ced Fix strict compiler warnings/errors 2018-11-15 16:31:26 +01:00
bdca863956 Units: Identifiers in Python
I only specified the identifiers for the units that are actually accessible for now.
This way we can postpone some decisions for now. E.g. if it should be `METER_SQUARE`, `SQUARE_METER`, `METER_SQ`, ...

Reviewers: brecht

Differential Revision: https://developer.blender.org/D3945
2018-11-15 14:40:22 +01:00
41216d5ad4 Cleanup: Remove more #if 0 blocks
Continuation of https://developer.blender.org/D3802

Reviewers: brecht

Differential Revision: https://developer.blender.org/D3808
2018-10-18 15:43:06 +02:00
4388549124 Units: Change '1000 Kilograms' to 'Tonnes'
Reviewers: brecht

Differential Revision: https://developer.blender.org/D3766
2018-10-04 17:52:17 +02:00
971ab57c7d Cleanup: style 2018-10-04 09:33:49 +10:00
2d21eb79ad Units: Support for fixed units
Users can select the main unit they want to use now.
Previously the displayed unit always depended on the magnitude of the value.
The old behavior can be restored by switching to the "Adaptive" mode for length, mass and time units.

Meters, kilograms and seconds are the default units for new and old scenes.

The selected unit is also the default unit for user input.
E.g. if cm is selected, whenever the user inputs a unitless number into a field of type length, it will be interpreted as cm.

Reviewer: brecht

Differential: https://developer.blender.org/D3740
2018-10-03 10:20:16 +02:00
0cff044d84 Spelling fixes in comments and descriptions, patch by luzpaz.
Differential Revision: https://developer.blender.org/D3719
2018-09-24 17:28:40 +02:00
636289b755 Fix multi-units drawing re precision handling.
This is still far from prefect, but yet much better than what we had so
far (more consistent with inheritent precision available in floats).

Note that this fixes some (currently commented out) units unittests, and
requires adjusting some others, will be done in next commit.
2017-08-01 16:42:35 +02:00
b6cb7b2c92 Fix two issues with recent changes to number display while editing them.
* Numbers with units (especially, angles) where not handled correctly
regarding number of significant digits (spotted by @brecht in T52222
comment, thanks).
* Zero value has no valid log, need to take that into account!
2017-07-31 15:43:14 +02:00
9953eeb012 Cleanup: use const for units API
Also make return args explicit.
2016-05-03 13:52:07 +10:00
5704ba7f9b Cleanup: style, spelling 2016-03-09 19:34:26 +11:00
f51ef8ac4d Correction to own previous rB9c0de0084bfe.
'1mm+1m' would fail with original fix, now consuming all alpha chars before checking unit again...
2016-03-02 18:12:14 +01:00
9c0de0084b Fix T47661: cm (centimeter) unit breaks m (meter) unit in Metric.
`m` unit when used after `cm`/`mm`/etc. ones would get ignored, and the alt version of miles
would be used instead.

The root of the issue is that, in `unit_find_str`, once we get a 'hit' for a unit, we check
it's actual unit (since 'm' would also hit on 'cm', 'mm', etc.). In case that hit is not a
valid unit one, we would just return NULL, breaking the cycle of checks over that unit, and
hence missing all later usages of it.

So now, in case we have an 'invalid unit hit', we immediately retry to find it within remaining string.
2016-03-02 18:02:19 +01:00
ae8e4d3718 Cleanup: redundant 'break', minor edits 2015-11-19 22:52:13 +11:00
86aeb7df96 Fix T46379: Bad behavior of bUnit_ToUnitAltName() with default units.
It would simply remove default units (in most case), cannot see any good reason for such behavior?
Might work in case default unit is the only one present, but breaks consistency (and it may not be
always obvious for user which unit it is). Comes from original patch from five years ago, rB7d8f0fce.

This will break keyboard-setting of values, e.g. '2m 33.4cm' would become '2 33.4cm',
totally useless and invalid entry!
2015-10-05 12:02:02 +02:00
2fe9224375 Fix T45459: Edge Length with Separate Units Displayed As 1m 100cm.
Our 'unit epsilon' was too small, given the fact we only display up to four digits usually...
2015-07-16 17:45:51 +02:00
b7c42ef93e Cleanup: use ascii as suffix (as with utf8) 2015-07-14 09:17:00 +10:00
bf69453ae7 BLI_string: add BLI_snprintf_rlen
use when the length of the destination string is needed.
2015-04-22 05:37:22 +10:00
b198500c02 Move bUnit_getScaleUnit -> BKE_scene_unit_scale
unit.c intentionally doesn't include DNA or BKE headers (except its own)
2014-08-26 20:53:41 +10:00
0e3fa0b761 Fix T41590: When scene scale is not 1.0, and units are "None," Blender assumes translations are in meters.
Turned out there were several issues in handling of scale parameter by numinput.
Fixed that by factorizing more some code in common with 'usual' numbuttons eval code
(new `bUnit_getScaleUnit()` helper will return valid scaled value, depending on
given system and type).

Now, numinput behaves as expected - using default unit amended by scale in case no unit is given
(i.e. entering '20' with a scale of 0.01 will give you 20cm, and '20cm' as well!).
2014-08-26 12:31:08 +02:00
27e7760913 BKE_units: Some cleanup (mostly bools instead of ints). 2014-08-20 12:31:15 +02:00
8535b9bd15 Fix T38722: Adding units in Imperial setting results in inconsistent values
Now always check for a default unit, and evaluate the whole expression in this "unit space".
Not an ideal solution, but should handle most cases nicely
(we can't address all possible corner cases anyway).

Note default unit is searched in current string first (bigger unit of current system wins),
then in previous string.

Note this also replaces ',' by '+' in default separation between units,
helps solving issues with parenthesis (e.g. (1'1")*2.5 would fail in existing code)!
This would break if someone uses py ops with lower precedence than '+' (like bitwise
operations, and comparison), but these are not expected usecase here anyway.

Reviewers: campbellbarton

Differential Revision: https://developer.blender.org/D340
2014-08-20 12:12:03 +02:00
5e3e095e2e Code Cleanup: use const 2014-07-12 09:09:24 +10:00
fa257adf96 Fix some loss of precision in BKE's unit code.
When converting text to value, units' "value" had only 6 digits of precision,
leading to annoying loss of precision esp. when mixing big and small units
(like e.g. miles and inches).
2014-06-17 16:06:12 +02:00
a2c107aef1 Code cleanup: use 'const' for arrays (blenkernel) 2014-04-27 00:25:15 +10:00
617557b08e Code cleanup: remove TRUE/FALSE & WITH_BOOL_COMPAT define 2014-04-01 15:22:28 +11:00
37026b12ec Code cleanup: use bool for static methods 2014-02-05 22:36:15 +11:00
d900f5be55 Code cleanup: use bools where possible 2014-02-03 19:35:44 +11:00
b9114cb609 UI: Use bool rather then int/short's where possible 2014-01-04 18:10:01 +11:00
e505203e8d Units: Add milligrams for mass
Avoids having small values displayed as "0kg".
2014-01-04 04:22:20 +01:00
4915706df6 Revert "Units: Make grams base unit for mass"
This reverts commit ead6d397fd.
2014-01-04 04:22:20 +01:00
ead6d397fd Units: Make grams base unit for mass 2013-12-31 18:10:30 +01:00
87cc890aef Support units in modal numinput
Summary:
This completly changes the way modal numinput is handled. Now, edited expression is a string, which then gets unit- and py-evaluated to get a float value.

We gain many power and flexibility, but lose a few "shortcuts" like '-' to negate, or '/' to inverse (if they are really needed, we still can add them with modifiers, like e.g. ctrl-/ or so).

Features:
- units (cm, ", deg, etc.).
- basic operations from python/BKE_unit (+, *, **, etc.), and math constants and functions (pi, sin, etc.).
- you can navigate in edited value (left/right key, ctrl to move by block) and insert/delete chars, e.g. to fix a typo without having to rewrite everything.
- you can go to next/previous value with (ctrl-)TAB key.
- As before, hitting backspace after having deleted all leading chars will first reset the edited value to init state, and on second press, the whole "modal numinput" editing will be cancelled, going back to usual transform with mouse.

Notes:
- Did not touch to how values are shown in header when modal numinput is not enabled (would do that in another commit), so this is still quite inconsistent.
- Added back radian support in BKE_unit.
- Added arcminute/arcsecond to BKE_unit.
(those unit changes affect all angle UI controls, btw, so you can now enter radians or longitude/latitude values when in degrees units).

Related to T37600.

Reviewers: brecht, campbellbarton, carter2422

Reviewed By: brecht, campbellbarton, carter2422
Thanks everybody!

Differential Revision: http://developer.blender.org/D61
2013-12-21 17:44:48 +01:00
dde5e5ce25 User Interface: Align number buttons labels to the left, number right 2013-12-11 21:27:13 +11:00
63caaa2b12 Code Cleanup: rename vars for detecting change to be more consistent
rename change/is_change/is_changed/modified -> changed
also use bools over int/short/char and once accidental float.
2013-11-26 06:39:14 +11:00
1a0fed9ee0 More fix for this stupid uppercase-to-lowercase convertion code... Thanks to Lockal for noting this! 2013-11-16 15:34:47 +01:00
d27f8103dd Fix [#37393] Input dimensions are case sensitive in the property panel, uppercase input is misinterpreted
Typo in lowercasing code!
2013-11-10 19:51:44 +00:00