Commit Graph

122 Commits

Author SHA1 Message Date
5ef717bec6 [#37327] Inconsistent numeric input conversion.
Issue was actually that micrometer was not drawing correctly (from r58165), reverted that fix and instead use utf8 drawing for editmode metrics when using a unit system (we already had a similar hack for surfaces and volumes, anyway).
2013-11-08 11:25:50 +00:00
991459d0ce fix [#36090] Blender displays strange symbol in edge length 2013-07-11 05:11:10 +00:00
46eb79c862 units: display 0.5mm rather then 500um, nicer when dealing with very small sizes but not microscopic. 2013-05-30 21:17:50 +00:00
2b2099cd51 Fix #34875: 0 digits of precision was not supported for FloatProperty, now
you can specify precision=0 for this, and use -1 for the default 2.
2013-04-08 18:55:08 +00:00
ffc8ecc587 use BLI_strncpy_rlen() rather then BLI_snprintf() when no formatting is needed.
also replace sprintf with strcpy when no formatting is done.
2013-03-14 10:39:18 +00:00
5162a155af Fix #34481: camera focal length and sensor size did not use units yet, now they do.
I've added a separate camera unit type. It's a bit strange to have an exception for
this but it ensures units are shown in familiar millimeters and it also ensures
backwards compatibility.
2013-03-13 17:16:49 +00:00
25c9b56c5a Suppress more uncommon units. 2013-02-11 07:12:15 +00:00
971fca48ca supress Hectograms from being used when displaying weight units since they are not so common. 2013-02-11 01:14:45 +00:00
f213ae0b19 style cleanup 2012-11-01 09:54:00 +00:00
aa49ca25d5 incorrect spelling in comments 2012-09-26 20:05:38 +00:00
b96c622015 style cleanup 2012-08-11 22:12:32 +00:00
715edceb42 spelling cleanup: metre -> er 2012-07-04 12:56:58 +00:00
32478997ec style cleanup 2012-06-27 18:29:47 +00:00
57b488574a style cleanup: comma placement 2012-05-23 22:45:39 +00:00
e701f9b670 style cleanup: whitespace / commas 2012-04-29 15:47:02 +00:00
f627745053 aparently yards are not used a lot, suppress their use in button display (input still knows about them) - was reported as a bug.
also fix minor rip bug where active selection was lost.
2012-04-20 14:59:24 +00:00
a73d0d3e72 code cleanup: dont include BLI_winstuff.h on non windows systems, also cleanup some defines/includes for windows. 2012-04-15 07:54:07 +00:00
3c6239f8be fix for unit system incorrectly replacint 'um' (unicode 'u'). with meters.
result was editing number buttons with um would give a python error.
2012-04-10 02:51:24 +00:00
6fef7f1c32 style cleanup: unit code 2012-03-10 14:20:55 +00:00
4f7bdc59d3 style cleanup: spelling.
also remove large, duplicate comments from sunsky.h
2012-03-09 00:41:09 +00:00
31d2ee9bf7 style cleanup, brackets in else/if, some indentation. 2012-03-06 18:40:15 +00:00
95670e03a0 style cleanup / comment formatting for bli/bke/bmesh 2012-03-03 20:19:11 +00:00
53fece44cf style cleanup for blenkernel, no functional changes. 2012-02-23 02:17:50 +00:00
96bd647c4f split some >120 lines, no functional changes 2011-12-21 22:56:06 +00:00
d227471b72 Fix #28663: All "unit" properties show a value of 0 (on WinXP&MinGW&scons)
Use %g instead of %lg due to %g is supposed to be used for doubles and %lg confuses mingw at all
2011-12-07 17:23:45 +00:00
33accdb725 use (const char*) rather than (char*) where possible.
also removed some unused function definitons.
2011-11-05 11:04:28 +00:00
4a04f72069 remove $Id: tags after discussion on the mailign list: http://markmail.org/message/fp7ozcywxum3ar7n 2011-10-23 17:52:20 +00:00
c912af36ca Fix #28663: All "unit" properties show a value of 0 (on WinXP&MinGW&scons)
Initially problem was caused by updated version of mingw-runtime which
changed behavior of snprintf and vsnprintf so %lf isn't anymore valid
for doubles.

According to manpages, %f is a correct format for snprintf for doubles.
2011-09-16 10:03:08 +00:00
b3704f45c4 Fixes for snprintf usage:
* replace by BLI_snprintf in various places, note _snprintf on windows
  does not properly null terminate the string.
* fix overflow in sequencer proxy code due to buffer being smaller than
  specified size.
* fix some usage of snprintf as strcpy, this is will go wrong if the
  string contains % characters.
* remove BLI_dynstr_printf function in gpu module, use BLI_dynstr_appendf
2011-08-30 10:07:50 +00:00
99caa9470e fix [#28213] Imperial unit for 0.001 inches inconsistently displayed as mils and thous 2011-08-11 08:24:56 +00:00
a8185f4cc8 patch [#26978] Minor Spelling Mistakes in Editor Operators
+ some errors I noticed.
2011-04-19 10:35:24 +00:00
b84a6c4d7e use less verbose string formatting for units and interface. 2011-03-29 14:36:55 +00:00
Nathan Letwory
0ff06e21cd doxygen: blender/blenkernel tagged. 2011-02-27 20:40:57 +00:00
00c05c8404 Clean up headers a bit more. 2011-02-23 18:03:40 +00:00
Nathan Letwory
5b607701a7 doxygen: prevent GPL license block from being parsed as doxygen comment. 2011-02-23 10:52:22 +00:00
0955c664aa fix for warnings from Sparse static source code checker, mostly BKE/BLI and python functions.
- use NULL rather then 0 where possible (makes code & function calls more readable IMHO).
- set static variables and functions (exposed some unused vars/funcs).
- use func(void) rather then func() for definitions.
2011-02-13 10:52:18 +00:00
b27f52ce24 bugfix [#25154] .MXF files should be included as a known video file type in the sequencer
[#25159] Vertex locations dont read correctly and are not labeled correctly in the properties bar.

- non rna buttons can now have units set.
- calls with invalid units system now raises an assert().
- include .mxf in filter.
2010-12-10 04:10:21 +00:00
68b49aa981 use unit system for the grid floor (was only ortho before). 2010-11-23 17:14:03 +00:00
0e9b664fce Changes to the ortho grid drawing based on discussion with Ton.
- ortho grid now draws scaled by the view3d 'Scale' setting, venomgfx noticed this was missing.
- so as not to confuse add scale next to unit display text, so rather then "Metres" it shows "Metres x 1.5" otherwise its confusing that grid lines are not in exact units.
- changed grid spacing to grid scale (needed for more logical behavior with units)
- when units are enabled grey out subdivisions.
2010-11-23 14:14:06 +00:00
3ae670fc02 fix [#24786] Setting Rotation Units to Radians doesn't affect the UI [33146] 2010-11-18 14:10:09 +00:00
fe8d5b81b0 use c90 compatible static initializers. 2010-11-03 06:31:53 +00:00
Nathan Letwory
ec6b9948ac Include BLI_math.h instead of math.h.
Silence a warning.
2010-10-21 07:29:15 +00:00
8408997c84 remove some unused code and reduced the scope if some vars (no functional change). 2010-10-05 21:22:33 +00:00
d2bc4a31a0 patch [#23796] Full support for unit buttons: area, volume, mass, velocity and acceleration
from Lorenzo Tozzi (oni_niubbo), suppress_only_shown.diff
2010-09-22 02:47:08 +00:00
e4f3a0efa6 patch [#23796] Full support for unit buttons: area, volume, mass, velocity and acceleration
from Lorenzo Tozzi (oni_niubbo), multiple patches: better_split.diff
2010-09-22 02:44:03 +00:00
b0f36f0317 patch [#23796] Full support for unit buttons: area, volume, mass, velocity and acceleration
by Lorenzo Tozzi (oni_niubbo)
2010-09-22 02:36:14 +00:00
36c273b1f7 - bone roll now in degrees not radians.
- rna buttons with units set now use the units base value for snapping. 
- bone head/tail radius could be set negative.

matt: removed a check in ui_is_but_unit() which made angle buttons return false, what was this for?
2010-09-16 04:19:22 +00:00
7d8f0fce7a patch [#23758] Better handling of UTF chars in UNITS fields (lengths, angles, etc.)
from Lorenzo Tozzi (oni_niubbo) with minor edits.

--- from the tracker
The present situation is this: due to bug#22274, during editing, UTF chars are stripped from buttons with a unit associated
(length, angles, etc.).
Example: if the button displays '90°' and you click on it with LMB, the editing string will become '90'.

The problem arises if you use microns: '34µm' becomes '34' that blender interprets as 34 meters. So clicking on a button
and hitting enter won't confirm the previous value, but will change it (very badly also).

Of course nobody is using microns in blender, but the problem will arise when we will implement areas and option 'Separate
Units' will be enabled. The value '2m² 3cm²' will become '2m' during editing.

This patch solves the problem rewriting the string in a smarter way than just stripping the UTF chars: the unit is translated
from unit->name_short ('µm') to unit->name_alt ('um'). So clicking on '34µm' the editing string will become
'34um'.
--- end

note: rather then allowing empty strings in name_alt field I made it so if the unit system was the default one a NULL name_alt will just strip the string, since its the default its not needed.
2010-09-15 17:37:00 +00:00
00877ceaae Fix [#21895] Incorrect calculations for measurement system
3d view grid scale text description wasn't using unit scale correctly
2010-04-05 05:32:16 +00:00
5369bd9c21 - template with an example of a modal operator drawing with opengl (draw a line on the screen)
- access to event.mouse_region_x/y
- basic type checking to callback functions (use PyCapsule names)
2010-02-28 09:36:02 +00:00